WBC Count Estimate The Mislabeled Specimen Lab Calculators Online
Lab Calculators

WBC Count Estimate

Field #1
WBCs
Field #2
WBCs
Field #3
WBCs
Field #4
WBCs
Field #5
WBCs
Field #6
WBCs
Field #7
WBCs
Field #8
WBCs
Field #9
WBCs
Field #10
WBCs

Estimate the patient’s WBC Count with a Wright-stained peripheral blood smear under 50x oil-immersion objective.

Formula:

Estimated WBC Count (in /ul) = Total WBCs seen in ten 50x oil-immersion objective fields / 10 x 3,000

Download TMS App The Mislabeled Specimen
Share to Social:
Subscribe
Notify of
0 Comments
Newest
Oldest Most Voted
Inline Feedbacks
View all comments